Do you take something like this in your cranium?

Do y'all experience like your house is ever dusty, in spite of how much y'all vacuum and clean? Accept you tried all the tricks – HEPA vacuum cleaners, air cleaners, taking your shoes off earlier coming in the business firm, washing the dog…. all to no avail?

Chances are adept that you lot're beingness plagued by a leaky duct and air handling system.

When y'all take leaks in your ducts (almost all duct are leaky) dust from the cranium gets sucked into the ducts and distributed throughout the business firm. Fifty-fifty if you have an excellent filtration system on your air handler, the grit can be sucked in from places that don't become filtered, and blown into your habitation, usually leaving fine gray grit everywhere.

Before yous telephone call in a heating/cooling (HVAC) contractor, there are a few steps that y'all can take yourself.

Alarm: working in an cranium tin can exist dangerous. Many attics don't have proper floors. Numerous people have taken bad steps and fallen through the ceiling, often resulting in serious injury or decease.

Assuming y'all are comfy working in the attic and can safely admission the duct work and air handling system, here are some things to bank check:

  1. Ensure that the air filter port is sealed air-tight.
    At least  10% of the systems I encounter look like the one in this movie. The air filter port is open and an over-sized filter is sticking out the side. Non only does this rob you lot of xx%-l% of your system'south efficiency(!) and cause the air to get extremely dry in the wintertime, only it sucks nasty, dusty attic air into the system where it is blown throughout the firm. Fix this simple problem  (get the right sized filter and record over the port) and you will see immediate energy savings and probably a much less dusty domicile.
  2. " data-medium-file="https://tedstips.files.wordpress.com/2012/01/view-inside-leaky-register-in-yellow-br.jpg?w=300" data-large-file="https://tedstips.files.wordpress.com/2012/01/view-inside-leaky-register-in-yellow-br.jpg?w=584" class="size-medium wp-image-1356" title="Poorly attached duct boot at register" src="https://tedstips.files.wordpress.com/2012/01/view-inside-leaky-register-in-yellow-br.jpg?w=300&h=113" alt="" width="300" height="113" srcset="https://tedstips.files.wordpress.com/2012/01/view-inside-leaky-register-in-yellow-br.jpg?w=300&h=113 300w, https://tedstips.files.wordpress.com/2012/01/view-inside-leaky-register-in-yellow-br.jpg?w=600&h=226 600w, https://tedstips.files.wordpress.com/2012/01/view-inside-leaky-register-in-yellow-br.jpg?w=150&h=57 150w" sizes="(max-width: 300px) 100vw, 300px">

    the duct "kicking" has a big gap

    Check your air registers around your house
    Your home's air registers should mostly exist clean. If some are much dustier than others, this is a sign of leaks most that particular register. Sometimes it volition be a leaky duct leading to it, other times it may be the register itself is poorly attached to the ceiling, providing a gap right into the cranium. I'k always suspicious when I meet a really dusty register.

  3. On a cold and windy day, plow off your forced air system (air conditioner, heat pump or furnace) and see if you tin experience a common cold breeze coming from whatsoever of the air registers in the business firm. The duct organization is supposed to be completely sealed, and so yous should never feel really cold air blowing in. You might feel cool air globe-trotting in due to the ducts being common cold, which causes the cool air to "drop" out of the ducts. But if you tin can correlate cold air blowing in with wind outside, yous're certain to accept leaks. The more than of a breeze you lot feel, the closer you are to the leak.
  4. Poorly attached duct

    Look effectually the cranium to see if any ducts are visibly detached or "askew", particularly at registers and ducts that failed test #3 above.
    These can exist hard to find, but sometimes it'due south pretty obvious. All the ducts should exist well-nigh and strongly attached at both ends – where it leaves the chief torso lines and where information technology feeds the ceiling registers or air returns.
    I've seen cases where the ducts have totally fallen off and are simply lying on in the insulation.
    Note: special tools and adhesives are used  to connect ducts in a permanent fashion. Do not attempt to repair these problems with "duct tape"! – this tape will fail and yous'll be left with leaky ducts again. Instead, industrial force nothing-ties and tensioning tools are used along with a sealant chosen "mastic."

  5. Sometimes problems are hidden in walls
    You might not exist able to discover any bug in the attic merely the problem could still lie in your ducts. Many duct systems run through walls and hidden cavities in your dwelling. It is even mutual  practice to use naked wall cavities without ducts! Contractors will just pick a wall, ceiling or flooring cavity and run air through it. This horrible do really shouldn't be permitted considering information technology causes so many problems.
    This type of trouble y'all probably tin't find yourself. A trained infrared thermographer (ofttimes an energy auditor or building scientist) may exist able to locate the problem, but sometimes it can be very difficult.
  6. Beware of Vermiculite
    Some older homes take Vermiculite insulation in the attic. These homes should non be tested using a blower door or duct blaster and y'all should not poke around in this textile because it may contain asbestos. Not all Vermiculite contains asbestos, but this is definitely a instance of "better safe than sorry."

I started this mail service saying that yous shouldn't phone call in your HVAC contractor and I'll terminate it by maxim the same affair. Many HVAC contractors are non trained to discover these leaks. Think about information technology – who created these leaky ducts in the first place?

As a building scientific discipline / energy consultant, I'yard biased because I'chiliad an contained consultant, and I recommend that you apply someone who is also independent to diagnose your issues. They might set up them likewise or they recommend a loftier-quality HVAC contractor whom they know to do good work. They will also have special equipment like a "blower door" and a "duct blaster" that allows them to quantify the leakiness of your ducts much more quickly and accurately than someone without these tools. In fact, without at least a blower door, information technology will be very difficult to fifty-fifty find many duct leaks.

Fixing duct leaks can assist make your firm much less dusty and information technology has the side effect of making it more comfortable and energy efficient. This is i of those things that you'll wish you lot had done years ago because it tin make your house more enjoyable to live in every 24-hour interval of the year.

Follow-ups:

"Why does house get dusty when oestrus on and not with ac on?"

Occasionally, weird things happen. If you've gotten this far, you know that the dust is unremarkably sucked in and distributed by the duct system. If that's and so, then how does the above situation occur?

There one possibility that comes to listen – moisture.

During the summer, the cold coils in the air conditioner are covered with water – this is the summer moisture getting drawn out of the air. When the dusty air moves through the coils, much of this grit could be trapped by that h2o. This would pb to much less dust when the air conditioner runs than when the heat is on.

"Does an energy audit bear witness why there is then much dust in the house?"

Someone else asked this question. The reply is "maybe."

If the free energy audit is a comprehensive review of your home, done by a competent technician, then aye, the audit should be able to show why your habitation is dusty. To brand sure, you lot should tell your auditor that you're having a dust problem and you'd like some help finding out why. If they look dislocated and don't advise issues similar the ones mentioned in this post, you should probably notice a unlike auditor!

"Why is the air and then dry in the wintertime?"

What does dry air have to do with a dusty firm? Mayhap everything!

If your duct organization is sucking dusty air in from the attic, information technology will likewise suck in the very cold, dry out air from the attic. When that dry out air enters your house, it sucks upwardly the moisture from your home similar sponge, resulting in very dry air. That's why an uncomfortably dry habitation in winter is a giveaway that the home is very leaky.

Keep in listen that the dry outside air could exist coming from anywhere. If yous have leaky windows and doors and a drafty house, information technology's also going to be uncomfortably dry. That said, nothing dries out a firm faster in winter than a leaky duct organisation that'southward sucking in cold, dry out outdoor air.